15 Parameter reference
15.2 Parameter list
852
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00165
C00166
C00167
51 L_SignalMonitor_a: Out3
52 L_SignalMonitor_a: Out4
53 L_MulDiv_1: Out
54 L_NSet_1: Target setpoint
Subcodes Lenze setting Info
C00164/1 0: No signal Logbook - analog element 1
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00164 | Logbook - analog elements
Data type: UNSIGNED_16
Index: 24411
d
= 5F5B
h
Parameter | Name:
C00165 | Error information
Data type: VISIBLE_STRING
Index: 24410
d
= 5F5A
h
Display of the error number divided into sectors in the event of an error
Subcodes Info
C00165/1 Status determining error
C00165/2 Current error
Read access Write access CINH PLC-STOP No transfer COM MOT Character length: 14
Parameter | Name:
C00166 | Error information text
Data type: VISIBLE_STRING
Index: 24409
d
= 5F59
h
Display of details on the status determining error and on the currently pending error
Subcodes Info
C00166/1 Resp. to status det. error
• Response to the status determining error
C00166/2 Subj. - status det. error
• Subject area of the status determining error
C00166/3 Mess. - status det. error
• Textual message of the status determining error
C00166/4 Resp. to curr. error
• Response of the currently pending error
C00166/5 Subj. - curr. error
• Subject area of the currently pending error
C00166/6 Mess. - curr. error
• Textual message of the currently pending error
Read access Write access CINH PLC-STOP No transfer COM MOT Character length: 31
Parameter | Name:
C00167 | Logbook data
Data type: OCTET_STRING
Index: 24408
d
= 5F58
h
This code is for device-internal use only and must not be written to by the user!