_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00449
C00453
Value is bit-coded: ( =bit set)
Bit 0 Relay_ON
Bit 1 DigOut1_ON
Bit 2 DigOut2_ON
Bit 3 DigOut3_ON
Bit 4 HighCurrent_ON
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00448 | DigOut decoupling value
Data type: UNSIGNED_16
Index: 24127
d
= 5E3F
h
Parameter | Name:
C00449 | FreqInxx_dnOut_p
Data type: INTEGER_32
Index: 24126
d
= 5E3E
h
From version 06.00.00
Output of the encoder position of the DI1/DI2 frequency input
Display range (min. value | unit | max. value)
-2147483647 Incr. 2147483647
Subcodes Info
C00449/1 FreqIn12_dnOut_p
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00453 | Keypad: Default manual jog
Data type: UNSIGNED_32
Index: 24122
d
= 5E3A
h
From version 14.00.00
Setting range (min. value | unit | max. value)
0.000 16000.000
Subcodes Lenze setting Info
C00453/1 729.001 Keypad: Speed setpoint
C00453/2 56.002 Keypad: Display bar