15 Parameter reference
15.2 Parameter list
916
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00510
C00516
C00517
Parameter | Name:
C00510 | PW protection config MCI
Data type: UNSIGNED_16
Index: 24065
d
= 5E01
h
From version 15.00.00
Configuration of the password protection for parameter access via fieldbus interface ("MCI")
Individual password protection for single communication channels
Setting range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 Reserved
Bit 1 Parameter write protection The fieldbus interface (MCI) cannot be used to write into
write/read parameters.
Bit 2 Parameter read protection The fieldbus interface (MCI) cannot be used to read
write/read parameters.
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Subcodes Lenze setting Info
C00510/1 0x0006 PW protection config. MCI
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00516 | Checksums
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00517 | User menu
Data type: INTEGER_32
Index: 24058
d
= 5DFA
h
When a system is installed, parameters must be changed time and again until the system runs satisfactorily. The
user menu of a device serves to create a selection of frequently used parameters to be able to access and change
these parameters quickly.
• Format: <code number>,<subcode number>
• If "0.000" is set, no entry will be displayed in the user menu.
Setting range (min. value | unit | max. value)
0.000 16000.000
Subcodes Lenze setting Info
C00517/1 51.000 C00051
: Display of actual speed value