15 Parameter reference
15.2 Parameter list
924
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00588
C00590
C00592
Parameter | Name:
C00588 | Resp. to max. speed at switching freq.
Data type: UNSIGNED_8
Index: 23987
d
= 5DB3
h
Response if the maximum speed for the set inverter switching frequency is reached (C00018)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00590 | Resp. to switching frequency red.
Data type: UNSIGNED_8
Index: 23985
d
= 5DB1
h
Response to reduction of the inverter switching frequency (C00018)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00592 | Resp. to CAN bus connection
Data type: UNSIGNED_8
Index: 23983
d
= 5DAF
h
Configuration of monitoring of the CAN interface (group 1)
"CAN on board" system bus
Selection list
0 No Reaction
1Fault
2Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes Lenze setting Info
C00592/1 0: No Reaction Response to incorrect telegram for CAN communication
C00592/2 0: No Reaction Response to "BusOff" (bus system switched off)
C00592/3 0: No Reaction Response to warnings of the CAN controller
C00592/4 0: No Reaction Response to communication stop of a CAN bus node
C00592/5 0: No Reaction Response to an event in the case of monitoring via
heartbeat protocol
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1