Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 949
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00677
C00678
C00679
Parameter | Name:
C00677 | L_GainOffsetP 1-3: Parameter
Data type: INTEGER_16
Index: 23898
d
= 5D5A
h
Gain and offset
Setting range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Lenze setting Info
C00677/1 100.00 % L_GainOffsetP_1
: Gain
C00677/2 0.00 % L_GainOffsetP_1
: Offset
C00677/3 100.00 % L_GainOffsetP_2
: Gain
C00677/4 0.00 % L_GainOffsetP_2
: Offset
C00677/5 100.00 % L_GainOffsetP_3
: Gain
C00677/6 0.00 % L_GainOffsetP_3
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00678 | L_GainOffsetPhiP 1-2: Parameter
Data type: INTEGER_32
Index: 23897
d
= 5D59
h
Gain and offset
Setting range (min. value | unit | max. value)
-2147483647 2147483647
Subcodes Lenze setting Info
C00678/1 65536 L_GainOffsetPhiP_1
: Gain
C00678/2 0 L_GainOffsetPhiP_1
: Offset
C00678/3 65536 L_GainOffsetPhiP_2
: Gain
C00678/4 0 L_GainOffsetPhiP_2
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00679 | L_MulDiv_2: Parameter
Data type: INTEGER_16
Index: 23896
d
= 5D58
h
The L_MulDiv_2 FB: Numerator and denominator
Setting range (min. value | unit | max. value)
-32767 32767
Subcodes Lenze setting Info
C00679/1 0 L_MulDiv_2
: Numerator
C00679/2 10000 L_MulDiv_2
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1