Chapter 6 Command
6-22
6.3.19 M code Release (Command : MOF)
(1) Program
(2) Description
Device Description
M0001A Axis X M code release input
D00000.1 Axis X error state
D00000.3 Axis X M code signal
Command MOF M code release
OP1 Slot Constant WORD Slot No. installed with positioning module
Operand
OP2 Axis PMLK,constant,D,Z,R,ZR WORD Command axis (0: axis X, 1: axis Y)
PMLK means P, M, L and K areas.
(a) When M code occurs, M code signal and M code No. are released at the same time (M code and M code No. are
changed to OFF and 0, respectively).
(b) It is available to be executed in operation.
(c) D device signal (axis X in Operation, etc) which used in the example above is an assumption that saving the axis state
value in D device area with SRD command.