Chapter 9 Functions
9-80
9.5.3 Speed Override
When user wants to change the operation speed of positioning control, user may change the speed with
speed override command.
(1) Characteristics of Control
(a) Speed override command is available in acc./steady speed area and available operation modes are “end”,
“go on” and “continuous”.
(b) It may be executed several times in operation.
(c) User may set speed override value as “%setting” or “speed setting” on [Speed override] of common
parameter.
(d) Related parameter setting (common parameter)
Items Setting value Description
0 : %setting Set the speed override setting value by %
Speed override
1 : speed setting Set the speed override setting value with exact number
(e) Auxiliary data of speed override command setting
Items Setting value Description
1 ~ 65535 (1=0.01%)
Set the speed override setting value with percentage
(If it is 100%, set 10000)
Speed
1 ~ Speed limit Set the speed override setting value directly
(2) Operation timing

Table of Contents