Chapter 10 Positioning Monitoring Package
10-10
10.3.2 Change of Position Operation Data
(1) How to Change the Position Operation Data
• You can change the operation data of each axis by using the positioning monitoring package. Note that you can’t
change the operation data during operation because PLC can’t save the operation data in flash memory.
• If you select the ‘axis X data’ or ‘axis Y data’ tabs in the positioning monitoring package, the window is invoked
where you can set the operation data of each axis as follows along with the operation data saved in XG5000.
• To change the operation data, first of all, change the operation data value to change, and select ‘Write PLC’.
Then the changed operation data is transferred to PLC, the operation data saved in PLC is changed.
Remark
• If you execute ‘Write PLC,’ the position parameter set in the positioning monitoring package and
the operation data of each axis are all transferred to XGB.
• The parameter and operation data displayed when the positioning monitoring package is
executed are not the data read from XGB but the parameter and operation data currently saved
in XG5000. Therefore if you change the parameter or operation data in the positioning monitoring
package, change the data after reading the data from XGB.
• Be sure to press the ‘Save Project’ button to save them in the XG5000 project. Otherwise the
settings of XG5000 I/O parameter might be different from XGB.