Chapter 8 Program
8-16
(2) Direct Start
(a) Condition of Direct Start
Condition of Direct Start Command (DST)
(b) Operating state by axis
According to exercise from “Chapter 8.1.2 Current State Reading,” it is a signal of “Operating” for each axis. It turns on
when it is operating. Direct Start command can not be configured while it is running hence configuration will only be
configured when it is not running. If you execute Direct Start while it is running, the “error 221” would be appeared.
(c) Error state for each axis
According to exercise from “Chapter 8.1.2 Current State Reading,” it is a signal of “Error state” for each axis. It turns on
when an error occurred. Operation will only work when there is no error. If you want to operate a system regardless of
errors, you can just inactivate the function.
(d) Address of Positioning Module
In this example, Positioning Module installed at the slot no.3.
(e) Axis of command execution
Set the axis to execute direct start
(f) Goal of Direct Start
Decide changing position of Direct Start command. In this example above, the initialized value is “device,” but you can
also change it with “real numbers,” which data type is “DINT.”
(g) Speed of Direct Start
Decide goal speed of Direct Start. In this example above, the initialized value is “device,” but you can also change it with
“real numbers,” which data type is “UDINT.”
(a) Condition of Direct Start
(b) Operating state by axis
(c) Error state for each axis
(d) Address of Positioning Module
(e) Axis of command execution
(f) Goal of Direct Start
(g) Speed of Direct Start
(h) Dwell Time of Direct Start
(i) Direct Start M code
(j) Direct Start Control Word