Label
Description
COM 1
Configuration options for COM1 interface
The settings that follow it apply only to this interface.
Interface
Type
Use this drop-down field to set the interface type for COM1. The options are as follows:
RS232, RS485 2-wire, RS485 4-wire, RS422
Drivers
Driver from list: Select a product/brand-specific driver to control your serial device.
User settings: If no suitable driver is available or you need to enter your own configuration pa-
rameters. These can be entered manually.
Baud rate: Enter the baud rate for communication here.
Data format: Select one of the settings for data bits, parity or stop bits
Handshake: Select a handshake (flow control) option.
Receive loops: This is a start counter for serial signals, i.e. how many cycles the
system goes through until it sends the data packet.
Driver
Select the driver that you want to load. Device drivers can be selected for the following brands:
AllanBradley, AMK, ASB, AtlasCopco, AVAT, Baumüller, Berger, Bosch, B&R, DanfossVLT,
Elau, F-Tron, GE_Fanuc, Hitachi, I-for-T, Indramal, IQ2000, KEB, Kuhnke, Lauer, Lenze, Locon,
Micro Innovation, Mitshubishi, Möller, Motoman, Npos, Omron, Parker Hauser CompaxC3, Phoenix,
Pilz, PLC Direct, Primo, Proface, Promicon, Quin, SCS Automata, Seidel Kollmorgen, SEW,
Siemens, Stoeber, Stromag, Sütron, Tsx37, Tsx47, Tsx57, Vectron, Vega Sensor, Voelkel Grenzlastreg-
ler, Winloc
Protocol
The protocol for communicating with the connected device: TCP
Port
Enter the port that will be used for communication.
Enable ports
through
firewall
Checking this box means that you can access the serial devices via the public address through
the port assigned above, without being blocked by the firewall.
Disable
Service
Checkbox for activating / deactivating the function.
If this function is activated, the serial driver for communication between
mbDIALUP / VCOM-LAN and the serial interface is not started.

Table of Contents

Other manuals for MB Connect Line mbNET Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MB Connect Line mbNET Series and is the answer not in the manual?

MB Connect Line mbNET Series Specifications

General IconGeneral
BrandMB Connect Line
ModelmbNET Series
CategoryNetwork Router
LanguageEnglish

Related product manuals