Page #161 background imageLoading...
Page #161 background image
Page 161 of 237
Version: 5.1.6 – June 4
th
, 2018
Temporarily saves the created rule.
Changes the order of the created rules.
ADVICE
You can enter address ranges in the input fields for the IP address.
Example of address ranges: 192.168.0.100-192.168.0.110 or 192.168.0.20/30
Address listings are not possible!
In the input fields for the ports, you can enter ranges or enumerations.
Example of a port range: 502-504
Example of port enumeration: 502,677,555
Both, range and enumeration can not be used simultaneously in the same field.
Ranges must be separated by a hyphen (-) and enumerated by comma (,).
No spaces between the elements to be separated!
The input of IP and port is not mandatory. If neither an IP nor a port is specified, a rule applies only to the selected
interfaces.