Page 213 of 237
Version: 5.1.6 – June 4
th
, 2018
Shows the user who dialed into the router via modem. The IP address of the PPP server
and PPP client (remote station) is displayed when a dial-up connection is successfully es-
tablished. The connections are always incoming connections. An active connection is in-
dicated by a green dot.
Information from
the last connection
Shows the connection time and the number of bytes sent and received during the most
recent connection as long as the router was not restarted or switched off in the interim.
This input field can be used to issue a command directly to the internal modem. This
function should only be used as directed by MB Connect Line support personnel.
Shows the type of connection and the assigned IP and DNS addresses.
Shows the commands sent to the modem to initialize it and the status of the connection
process. The error messages that occur when establishing the connection are also dis-
played here.
Manual Control of
the GSM modem
You can use this button to restart the internal modem. This function should only be
used as instructed by MB Connect Line support personnel.
Specifies the current network availability in percent and dBm. If you have an mbNET with
mobile broadband and UMTS, the device will automatically change networks when UMTS
becomes available again or UMTS is no longer available.
Shows the respective transmission method. The following are possible:
□ GSM/GPRS
□ EDGE
□ UMTS
Shows the current mobile broadband provider (T Mobile Germany as shown in Figure
211).
Shows the status of your SIM card in mbNET.
Shows all events and errors related to the GSM modem.