© 2011 MIMAKI ENGINEERING CO.,LTD. 1.1.2 R.2.0 P.1
Maintenance Manual > Operating Principle > Basic Operation > Sequence at POWER OFF
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0
1.1.2 Sequence at POWER OFF
Sequence at turning OFF the power supply
The flow until the power supply is turned OFF is as below:
No. Item Process content
1 UV Power OFF Turns OFF the power supply of the UV lamp unit.
2 Moving to local If the status is other than local, changes it to local.
3 Saving parameter Saves the parameters below when the power supply is turned OFF.
• Saving the parameter value
• Backup of the parameter to F-ROM
In addition, performs check sum and displays ERROR817 (save area error) when an error occurs.
4 Moving head to capping
position
Moves the head to the capping position if it stays away from that position.
* Depending on the mode, it may not return to the capping position.
5 Turn Power of SLIDER PCB
OFF
6 Saving event log Saves turning OFF the power supply to the event log.
7Power OFF