Accessible via MENU - [Operating] - [System setup]- [Weighing points]- [Weighing
point x]- [Parameters] .
WP-D
Max 1000kg d= 1kg
0
kg
Weighing points @admin
Weighing point A
Weighing point B
Weighing point C
Weighing point D
Internal weighing point
Internal weighing point
xBPI scale
Liquid counter
Parameters
WP-D
Max 1000kg d= 1kg
0
kg
Weighing points @admin
Weighing point D
Settings locked
W&M
Max
Scale interval
Scale Weight /
Liquid counter
none
1000 kg
1
1 kg
Default Save
[Settings locked]
The weighing point settings and assignment can only be viewed as if the
corresponding CAL switch were closed; see Chapter 2.7.1.
[W&M]
Setting for operation in legal metrology.
Selection: [None], OIML, NTEP (for USA) or NSC (for Australia), see Chapter 4.7.1.1.1.
[Max]
Maximum capacity, see Chapter 4.7.1.2.1.1.
[Scale interval]
See Chapter 4.7.1.2.1.2.
[Weight /]
Weight increase per n scale counts.
Setting range: 0.00010…9999999 in t, kg, g, mg, lb or oz.
1. In this case: Select [Weighing point D] with [Liquid counter] and press the
[Parameters] soft key.
A selection window opens.
2. Select and conrm the individual parameters.
4 System setup Process Controller Maxxis 5 PR 5900
EN-125 Minebea Intec