Technical data
Description Data
Transfer rate 10 Mbit/s and 100 Mbit/s
Auto-detection (10/100, HalfDX/FullDX)
Protocol EtherNet IP
Connection mode Network
Conguration EDS le "sag_5410_ethernetip.eds"
Potential isolation Yes
Cable type Twisted pairs, screened, e.g., patch cable CAT5 Autolink (stra-
ight or crossover)
Cable impedance
150
Cable length to HUB Max. 115 m
Certicate EtherNet IP specication
- ODVA le no. 10286
- Test date: 09/06/2005
- Vendor ID 90
- See also: www.odva.org
- Industry-compatible CE, UL, and cUL
Note:
The EtherNet IP card is supported by PR 5410 rmware release 1.30 or higher.
The IP address and subnet mask are set under - [Fieldbus parameters] (see also
Chapter 7.17.5 and 12.2).
The EDS le is stored on the CD supplied with the device (eldbus directory of the
respective device). The current le is also available to download online:
http://www.minebea-intec.com
4.6.16.1 Controls on eldbus card
NOTICE
The DIL switch settings will not be used.
Make sure that the switches 18 are set to position "OFF."
Settings are dened via - [Fieldbus parameter].
X3 Process Indicator PR 5410 4 Device installation