9.2.7.2 Saving an alibi data record
Requirements:
In menu -[Operating parameter][Use alibimemory], the [Gross, Net, Tare] parameter
is selected.
Procedure:
After a weighing operation, press the key or complete lling.
The weight data is written into the alibi memory.
Example:
Operating sequence; see also Chapter 13.4
1 Write request X120 Start printing and save data record
1a Wait X120 = 0
1b Wait X49 (Command active) = 0
1c Check X48 (Command error) = 0
2 Read request D16 Gross weight
3 Read request D17 Net weight
4 Read request D18 Tare weight
5 Read request D19 Sequence number for alibi memory
6 Read request D21 Date (in BCD display)
7 Read request D22 Time (in BCD display)
9.2.7.3 Exporting alibi data records
Example:
Operating sequence; see also Chapter 13.4
1 Write request D19 Sequence number for alibi memory
2 Write request X122 Export selected data record from alibi me-
mory.
2a Wait X122 = 0
1b Wait X49 (Command active) = 0
1c Check X48 (Command error) = 0
2 Read request D16 Gross weight
3 Read request D17 Net weight
4 Read request D18 Tare weight
6 Read request D21 Date (in BCD display)
7 Read request D22 Time (in BCD display)
X3 Process Indicator PR 5410 9 Extended functions
Minebea Intec EN-278

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec X3 Process Indicator PR 5410 and is the answer not in the manual?

Minebea Intec X3 Process Indicator PR 5410 Specifications

General IconGeneral
BrandMinebea Intec
ModelX3 Process Indicator PR 5410
CategoryTouch Panel
LanguageEnglish