Switch settings
PR 5410-1 PR 5410-2 PR 5410-3 PR 5110
ON: S1
OFF: S2, S3, S4, S5
ON: S1
OFF: S2, S3, S4, S5
ON: S1, S3, S4, S5
OFF: S2
ON: S1, S2, S3
OFF: S4, S5
Conīž·guration
PR 5410-1 PR 5410-2 PR 5410-3 PR 5110
- [Serial ports para-
meter]- [Remote display]-
[Slot 1/2 RS485]
[Param][Mode multiple
transmitters]
[Param] - [Device Id A]
[Param] - [Next Device
Id B]
- [Serial ports para-
meter]- [Remote display]-
[Slot 1/2 RS485]
[Param][Mode multiple
transmitters]
[Param] - [Device Id B]
[Param] - [Next Device
Id C]
- [Serial ports para-
meter]- [Remote display]-
[Slot 1/2 RS485]
[Param][Mode multiple
transmitters]
[Param] - [Device Id C]
[Param] - [Next Device
Id A]
[ ]- [oP 10]- [LInE]-
[rS485]
[ ]- [oP 12]- [tokEn]-
[ActIvE]
[ ]- [oP 13]- [SEnd-
ModE]- [SEnd]
[ ]- [oP 14]- [WEIght]-
[FolloW]
[ ]- [oP 15]- [WPkEy]-
[SElEct]
X3 Process Indicator PR 5410 4 Device installation
Minebea Intec EN-68