Table 7-44 Programmable I/O Screen Components
Screen Components Description
Mode Depending on the selected system variable, di󰀨erent settings are
possible.
Rising for ags and digital inputs and outputs
The digital output will be set or reset if the state of the variable
changes from FALSE to TRUE or OFF to ON.
Rising for numbers and analog inputs and outputs
The digital output will be set or reset if the value of the system
variable rises above a dened threshold.
Falling for ags and digital inputs and outputs
The digital output will be set / reset if the state of the variable
changes from TRUE to FALSE or ON to OFF.
Falling for numbers or analog inputs and outputs
The digital output will be set / reset if the value of the system variable
falls below a dened threshold.
Change
The digital output will be set / reset if the value of the system variable
changes.
Not available for decimal numbers or times.
Threshold Denes the threshold above or below which the output is turned on or
o󰀨.
Not available for ags and digital inputs or outputs.
Delay Delay time between the on or o󰀨 condition being fullled and the output
being turned on or o󰀨.
Modulo Denes how often a condition has to be fullled in order to turn the
output on or o󰀨.
A module of 2 on the ON condition would require the ON condition to be
fullled 2 times before the output was turned on.
Programmable I/O - continued
7-71
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
E-MULTI CONTROLLER HMI INTERFACE
E-Multi Controller User Manual