8.6 Service and Repair The Controller
WARNING
Always isolate your controller at source before you open the unit to inspect
it or replace fuses.
8.6.1 Replacement Parts
Mold-Masters does not expect that you will need to repair any controller parts
at board level other than fuses. In the unlikely event of any board failure then
we provide an excellent repair and exchange facility for all our customers.
8.6.2 Cleaning and Inspection
CAUTION
External cables should be checked to see that there has been no damage
to the exible conduit, plugs or sockets. If the exible conduit has been
damaged or if there are any exposed conductors, the loom must be
replaced.
CAUTION
Every environment suers some degree of contamination, necessitating the
need to inspect the fan lters at regular intervals (monthly is recommended).
If lters are clogged, they need to be replaced. Replacement lters can
be obtained from Mold-Masters. Please quote the model type and year of
manufacture.
Any excess dust that has entered into the cabinet may be removed with a
light brush and vacuum cleaner.
If the equipment is subject to vibration, we recommend you use an insulated
screwdriver to check that no terminals have become loose.
8-6
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
MAINTENANCE