7.26 Programmable I/O
This section describes the settings for programmable digital outputs. For
each output ON and OFF conditions can be dened. These conditions are
dened using system variables.
Figure 7-30 Programmable I/O screen
Table 7-44 Programmable I/O Screen Components
Screen Components Description
DO Status of the digital output (active / inactive).
The output is on when the box is lled.
Active Denes if the programmable output is used or not.
HW-Path Displays the PLC output being controlled
Functionality Used to describe how the output is used, e.g. COLOR MIXER
System variable Which variable will be used to turn the output on or o󰀨.
The drop down list displays the variables in the IO Param variable group.
Additional variables may be added as required.
7-70