Section 6 - Operation
WARNING
Ensure that you have fully read “Section 3 - Safety” before operating your
E-Multi controller.
CAUTION
Although the main switch has the capacity to switch the whole system o, it
is recommended that this is only done in an emergency.
The controller uses computer technology and should be switched o in
stages.
A sequenced method for switching on and o protects the console and
keeps the switched load to a minimum to extend the life of the main isolator.
CAUTION
6.1 Introduction
Before the E-Multi can be used, the controller will need to be set up.
Please see Section 9 for details on setting parameters such as:
• Heating
• Control
• Injection speeds
• Trigger signals, etc.
6.2 Isolate the Controller
For all E-Multi controllers, the main power switch is a rotary circuit breaker
at the rear of the cabinet. This switch is rated to safely handle the total load
current during switch on and switch o.
You can use a suitably-sized padlock, or similar device to lock the switch in
the o position to lockout electrical supply during maintenance.
Figure 6-1 E-Multi main power switch
6-1
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
OPERATION
E-Multi Controller User Manual