Section 6 - Operation
WARNING
Ensure that you have fully read “Section 3 - Safety” before operating your
E-Multi controller.
CAUTION
Although the main switch has the capacity to switch the whole system o󰀨, it
is recommended that this is only done in an emergency.
The controller uses computer technology and should be switched o󰀨 in
stages.
A sequenced method for switching on and o󰀨 protects the console and
keeps the switched load to a minimum to extend the life of the main isolator.
CAUTION
6.1 Introduction
Before the E-Multi can be used, the controller will need to be set up.
Please see Section 9 for details on setting parameters such as:
Heating
Control
Injection speeds
Trigger signals, etc.
6.2 Isolate the Controller
For all E-Multi controllers, the main power switch is a rotary circuit breaker
at the rear of the cabinet. This switch is rated to safely handle the total load
current during switch on and switch o󰀨.
You can use a suitably-sized padlock, or similar device to lock the switch in
the o󰀨 position to lockout electrical supply during maintenance.
Figure 6-1 E-Multi main power switch
6-1
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
OPERATION
E-Multi Controller User Manual