17 Specifications
200 SRM-3006 Narda
17.5.3 General specifications
Compliance
Dimensions and weight
Calibration
Operating temperature range -10 °C to +50 °C (same as SRM-3006 basic unit)
Air humidity < 29 g/m
3
(< 93% at +30 °C)
Climatic Storage 1K3 (IEC 60721-3),
extended to -10 °C to +50 °C
Transport 2K4 (IEC 60721-3)
Operating 7K2 (IEC 60721-3)
Mechanical Storage 1M3 (IEC 60721-3)
Transport 2M3 (IEC 60721-3)
Operating 7M3 (IEC 60721-3)
ESD and EMC EN 61326:2006
Safety EN 61010-1:2004
EU Guidelines 2003/11/EG 06.02.2003 (PBDE and OBDE)
2002/95/EG 27.01.2003 (RoHS)
2002/96/EG 27.01.2003 (WEEE)
CE (European Community) Ye s ( Declaration of Conformity on page 205)
Country of origin Germany
Dimensions Length: 460 mm
Antenna head dimensions: 135 x 90 mm
Weight 450 g
Calibration 24 reference points
The SRM-3006 applies linear interpolation between
reference points.
Recommended calibration
interval
24 months