WWW.NNC.IR
Macro Reference
480
Vision System FH/FZ5 Series
User’s Manual (Z340)
Example
Uses the *MEASUREDISPG subroutine of the Unit Macro processing unit to draw a cross-hair cursor at the
measured coordinates by the search processing unit (Processing Unit number 5). The measured X and Y
coordinates can be gotten with External Reference Data numbers 6 and 7 respectively.
To display the string at the fixed position regardless of the position compensation result, specify the assigned
processing unit number to this Unit Macro processing unit (where the *MEASUREDISPG subroutine is used)
for the <unitNo> parameter.
Useable Modules
Unit macro
Supported Versions
Version 3.50 or later
Related Items
*MEASUREDISPG
Rem Get the measurement result.
GetUnitData 5, 6, X#
GetUnitData 5, 7, Y#
Rem Draw the image
DrawCursor Int(X#), Int(Y#), 0, UnitNo
Return
GetUnitData (Reference: X Details (p.552)) Int (Reference: X Details (p.575))
SetDrawStyle (Reference: X Details (p.700)) UnitData (Reference: X Details (p.778))
UnitNo (Reference: X Details (p.790)) Ut (Reference: X Details (p.793))

Table of Contents

Other manuals for Omron SYSMAC FH Series

Related product manuals