M10 AT Commands Set
M10_ATC_V1.01 - 27 -
OK
Parameter
<value> 0 DCD line is always ON
1 DCD line is ON only in the presence of data carrier
Reference
V.25ter
Note
2.2.28 AT&D Set DTR Function Mode
AT&D Set DTR Function Mode
Response
This parameter determines how the TA responds when circuit 108/2(DTR)
is changed from the ON to the OFF condition during data mode.
OK
Execution
Command
AT&D[<value>]
Parameter
<value> 0 TA ignores status on DTR
1 ON->OFF on DTR: Change to Command mode with
remaining the connected call
2 ON->OFF on DTR: Disconnect call, change to
Command mode. During state DTR = OFF is auto-answer off.
Reference
V.25ter
Note
2.2.29 AT&F Set All Current Parameters To Manufacturer Defaults
AT&F Set All Current Parameters To Manufacturer Defaults
Response
TA sets all current parameters to the manufacturer defined profile.
OK
Execution
Command
AT&F[<value>]
Parameter
<value>
0 set all TA parameters to manufacturer defaults.
Reference
V.25ter
Note
2.2.30 AT&V Display Current Configuration
AT&V Display Current Configuration
Response
TA returns the current parameter setting.
<current configurations text>
OK
Execution
Command
AT&V[<n>]
Parameter
<n>
0 profile number
Reference
V.25ter
Note