M10 AT Commands Set
M10_ATC_V1.01 - 49 -
Reference
GSM 07.07 [13]
Note
3.2.17 AT+CKPD Keypad Control
AT+CKPD Keypad Control
Test Command
AT+ CKPD=?
Response
OK
Parameters
Write Command
AT+CKPD=[<ke
ys>
[,<time>[,<pause
>]]]
Response
TA emulates ME keypad by giving each keystroke as a character in a
string <keys>. <time>*0.1 seconds is the time to stroke each key and
<pause>*0.1 seconds is the length of pause between two strokes.
Keystrokes <keys> are emulated.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<keys> string of characters representing keys as listed in the
following table (based on PCCA STD-101 Annex
table I-3):
Char.: ASCII-Code: Note:
# 35 hash (number sign)
* 42 star (*)
0... 9 48... 57 number keys
: 58 escape character for manufacturer
specific keys
D/d 68/100 volume down
E/e 69/101 connection end (END)
R/r 82/114 recall last number (R/RCL/MR)
S/s 83/115 connection start (SEND)
U/u 85/117 volume up
<time> 0...255 seconds (default value is manufacturer specific, but
should be so long that a normal ME can handle
keystrokes correctly)
<pause> 0... 25.5 seconds (default value is manufacturer specific, but
should be so long that a normal ME can handle keystrokes correctly)
Reference
GSM 07.07 [13]
Note
3.2.18 AT+CLCC List Current Calls Of ME
AT+CLCC List Current Calls Of ME
Test Command Response