Common Analysis and Display Functions
R&S
®
FSVA3000/ R&S
®
FSV3000
441User Manual 1178.8520.02 ─ 01
Use Zoom Limits ← Search Limits
If activated, the peak search is restricted to the active zoom area defined for a single
zoom.
Remote command:
CALCulate<n>:MARKer<m>:X:SLIMits:ZOOM[:STATe] on page 992
Deactivating All Search Limits ← Search Limits
Deactivates the search range limits.
Remote command:
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe] on page 990
CALCulate<n>:THReshold:STATe on page 993
9.3.3.3 Positioning Functions
Access: [MKR ->]
The following functions set the currently selected marker to the result of a peak search
or set other characteristic values to the current marker value.
Peak Search ...............................................................................................................441
Search Next Peak ...................................................................................................... 441
Search Minimum ........................................................................................................ 442
Search Next Minimum ................................................................................................442
Center Frequency = Marker Frequency ..................................................................... 442
Reference Level = Marker Level ................................................................................ 442
Peak Search
Sets the selected marker/delta marker to the maximum of the trace. If no marker is
active, marker 1 is activated.
For spectrogram displays, define which frame the peak is to be searched in.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum[:PEAK] on page 994
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK] on page 997
Search Next Peak
Sets the selected marker/delta marker to the next (lower) maximum of the assigned
trace. If no marker is active, marker 1 is activated.
For spectrogram displays, define which frame the next peak is to be searched in.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum:NEXT on page 994
CALCulate<n>:MARKer<m>:MAXimum:RIGHt on page 995
CALCulate<n>:MARKer<m>:MAXimum:LEFT on page 994
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT on page 997
CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt on page 998
CALCulate<n>:DELTamarker<m>:MAXimum:LEFT on page 997