Useful commands for occupied bandwidth measurements described elsewhere
Configuring the channel:
●
[SENSe:]POWer:ACHannel:BANDwidth[:CHANnel<ch>]
●
[SENSe:]POWer:ACHannel:PRESet
●
[SENSe:]POWer:ACHannel:PRESet:RLEVel
Defining search limits:
●
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe] on page 990
●
CALCulate<n>:MARKer<m>:X:SLIMits:LEFT on page 991
●
CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt on page 991
Performing the measurement:
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:SELect on page 750
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>[:STATe] on page 750
Retrieving results:
●
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:RESult? on page 749
Remote commands exclusive to occupied bandwidth measurements:
[SENSe:]POWer:BWIDth................................................................................................ 790
[SENSe:]POWer:BANDwidth...........................................................................................790
[SENSe:]POWer:BWIDth <Percentage>
[SENSe:]POWer:BANDwidth <Percentage>
This command selects the percentage of the total power that defines the occupied
bandwidth.
Parameters:
<Percentage> Range: 10 PCT to 99.9 PCT
*RST: 99 PCT
Default unit: PCT
Example:
POW:BAND 95PCT
Manual operation: See " % Power Bandwidth " on page 203
14.5.5.2 Programming Example: OBW Measurement
This programming example demonstrates the measurement example described in
Chapter 7.5.5, "Measurement Example", on page 205 in a remote environment.
//-----------Preparing the measurement ------------
//Reset the instrument
*RST
//-------------Configuring the Measurement-----------------------
//Set the center frequency to 800 MHz.
FREQ:CENT 800MHz
//Set the reference level to -10 dBm.
Configuring and Performing Measurements