• If you do this, then the machine will reset the PM counter for the fusing unit automatically, after
you turn the power on again.
Do not do this if you replace the complete fusing unit. This is because the fusing unit has a new
detection mechanism.
2. Turn off the main power switch.
3. Open the right door.
4. Front fusing stopper [A] ( x 1)
5. Rear fusing stopper [B] ( x 1)
6. Release the lock levers [A].
7. Hold the fusing unit handles [B], and then pull out the fusing unit.
Pressure Roller Lamp
1. Fusing unit (*p.248 "Fusing Unit")
Fusing
249