4. Appendix: Process Control Error
Conditions
Process Control Error Conditions
Developer Initialization Result
SP-3-014-001 (Developer Initialization Result)
No. Result Description Possible Causes/Action
1
Successfully
completed
Developer initialization is
successfully completed.
-
2
Forced
termination
Developer initialization
was forcibly terminated.
• A cover was opened or the main switch was
turned off during the initialization.
1. Do the developer initialization again when
done in SP mode. Reinstall the engine main
firmware if the result is the same.
2. Turn the main switch off and on when done
at unit replacement.
6 Vt error
Vt is more than 0.7V when
Vcnt is 4.3V.
1. Make sure that the heat seal on the
development unit is not removed.
2. Defective TD sensor
7 Vcnt error 1
Vcnt is less than 4.7V
when Vcnt is Vt target
±0.2V.
1. Defective TD sensor
2. Vt target settings are not correct.
3. Toner density error
8 Vcnt error 2
Vt is more than 0.7V when
Vcnt is 4.3V and Vcnt is
less than 4.7V when Vcnt
is Vt target ±0.2V.
1. Make sure that the heat seal on the
development unit is not removed.
2. Defective TD sensor
9 Vcnt error 3 Vcnt is less than 4.7V.
1. Make sure that the heat seal on the
development unit is not removed
2. Defective TD sensor
3. Vt target settings are not correct.
4. Toner density error
113
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MPC 2800 AT-C2 and is the answer not in the manual?

Ricoh MPC 2800 AT-C2 Specifications

General IconGeneral
BrandRicoh
ModelMPC 2800 AT-C2
CategoryAll in One Printer
LanguageEnglish

Related product manuals