No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
870
CTL
B
Address book error
An error is detected in the data copied to the address book over a network.
• Defective software program
• Defective HDD
• Incorrect path to the server
1. Initialize the address book data (SP5-846-050).
2. Initialize the user information (SP5-832-006).
3. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
872
CTL
B
HDD mail data error
An error is detected in the HDD at machine initialization.
• Defective HDD
• Power failure during an access to the HDD
1. Turn the main switch off and on.
2. Initialize the HDD partition (SP5-832-007).
3. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
873
CTL
B
HDD mail transfer error
An error is detected in the HDD at machine initialization.
• Defective HDD
• Power failure during an access to the HDD
1. Initialize the HDD partition (SP5-832-008).
2. Replace the HDD.
3. Appendix: Service Call Conditions