Instrument Function
R&S
®
SMBV100A
205Operating Manual 1407.6062.32 ─ 08
"Ext Triggered"
The pulse generator signal is triggered by an external trigger event. The
trigger signal is supplied via the PULSE EXT connector.
Example: Generation of pulse signals using trigger modes Ext
Triggered (Single Pulse)
The measurement were made using a 6-dB-attenuator.
Parameter Value
Trigger Mode Ext Triggered
Double Pulse State Off
External Trigger Input Slope Positive
Pulse Delay 100 ns
Pulse Width 100 ns
Pulse Period -
Channel
1
= Indicates the external trigger signal which is input at the PULSE EXT con-
nector. The positive slope is active.
Channel
2
= Indicates the sync signal. The sync signal starts after a trigger delay of typi-
cally 50 ns (see specifications). The sync signal is output at the PULSE
SYNC connector.
Channel
3
= Indicates the pulse signal. The pulse signal starts after the set pulse delay of
100 ns. It is output at the PULSE VIDEO connector.
Example: Generation of pulse signals using trigger modes Ext
Triggered (Double Pulse)
The measurement were made using a 6-dB-attenuator.
Parameter Value
Trigger Mode Ext Triggered
Double Pulse State On
External Trigger Input Slope Negative
Pulse Width 100 ns
RF Signal and Analog Modulations - RF Block