EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Page 370

Rohde & Schwarz SMBV100A
780 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instrument Function
R&S
®
SMBV100A
353Operating Manual 1407.6062.32 ─ 08
Segment Restart
Enables/disables the generation of an additional marker restart signal in the output wave-
form file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
"Disable"
No additional marker is generated.
"Marker
1/2/3/4"
Generates a restart marker signal at the beginning of each segment for
the corresponding marker.
The segment begin is defined by the low-high slope of the marker. This
applies for switching between two segments as well as in case of seg-
ment replay.
SCPI command:
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:MARKer:ESEGment
on page 543
Output File
In the Output File section, the output file name is specified and a comment can be added
to the file.
Comment
Adds a comment to the multi segment file.
SCPI command:
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:COMMent on page 542
Output file
Opens the File menu, where the file name of the multi segment waveform which has to
be calculated can be entered. The multi segment waveform is saved under this name by
clicking the "Create" or "Create and Load" button.
A name must also be entered here before the list can be saved as a configuration file
("Save List"). In this case the name is needed for internal storage procedures. It is entered
as the default name for the multi segment waveform file when loading the list.
SCPI command:
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:OFILe on page 544
Handling of Multi Segment Files
The buttons in this sections are provided for handling of the multi segment files.
Save List
Saves the current entries of the table in a configuration file, including the level mode,
clock mode, segment marker mode and output file name settings.
The file name is entered in the "File" menu. Configuration files have the file extension
*.inf_mswv. They can be used later as the basis for further multi segment waveforms.
Baseband Signal - Baseband Block

Table of Contents

Other manuals for Rohde & Schwarz SMBV100A

Related product manuals