The signal period can be set by the user in the "Signal Period" field.
Shorter I/Q files are repeated periodically, and only the first part of lon-
ger I/Q files is used.
SCPI command:
[:SOURce<hw>]:BB:ARB:MCARrier:TIME:MODE on page 534
Signal Period
Sets the signal period in Signal Duration Mode "User". Shorter I/Q files are repeated
periodically, and only the first part of longer I/Q files is used.
SCPI command:
[:SOURce<hw>]:BB:ARB:MCARrier:TIME on page 534
Carrier Table Submenu
Calls the table for configuring individual carriers. A selectable carrier range can be set
with the aid of the optional "Carrier Table Assistant" (see "Muti Carrier
Table" on page 365).
The multi carrier configuration can be checked with the aid of the "Carrier Graph".
Carrier Graph
Calls a graphical representation of the current multi carrier configuration in the frequency
domain.
The height of the bars corresponds to the chosen gain of each individual carrier. The
bandwidth of the carriers signals is indicated by the width of the bars.
Output Settings
The "Output Settings" section in the multi carrier main menu indicates the name, the size
and the clock rate of the currently calculated multi carrier output file.
File
Opens the "File" menu, where the output file name of the multi carrier waveform which
has to be calculated can be entered.
The multi carrier waveform is calculated and saved under this name by clicking the
"Create" or "Create and Load" button.
SCPI command:
[:SOURce<hw>]:BB:ARB:MCARrier:OFILe on page 532