Remote Control Commands
R&S
®
SMBV100A
462Operating Manual 1407.6062.32 ─ 08
Example:
DISP:ANN:AMPL ON
shows asterisks instead of level values.
:DISPlay:ANNotation:FREQuency <State>
Fades out frequency display in the header of the instrument and displays asterisks
instead.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example:
DISP:ANN:FREQ ON
shows asterisks instead of the frequency.
:DISPlay:ANNotation[:ALL] <State>
Fades out level and frequency display in the header of the instrument and displays aster-
isks instead. These settings are particularly useful when you remotely control the instru-
ment.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example:
DISP:ANN:AMPL ON
shows asterisks instead of frequency and level values.
:DISPlay:DIALog:CLOSe <DialogId>
Closes the specified dialog. To determine the dialog identifier, use command :
DISPlay:DIALog:ID.
Setting parameters:
<DialogId> string
Example:
DISP:DIAL:CLOS "<dialog ID>"
closes the dialog, determined with the "<dialog ID>".
Usage: Setting only
:DISPlay:DIALog:ID
Returns the dialog identifiers of the open dialogs in a string separated by blanks.
Parameters:
<DialogIdList> string
Example:
DISP:DIAL:ID?
Response: "<dialog ID(1)> <dialog ID(2)> ...
<dialog ID(n)>"
returns the Ids of all opened dialogs.