Remote Control Commands
R&S
®
SMBV100A
514Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:BB:ARB:TRIGger[:EXTernal<1|2>]:DELay <Delay>
The command specifies the trigger delay (expressed as a number of samples) for external
triggering.
The numeric suffix to EXTernal distinguishes between the external trigger via the TRIG-
GER 1 (suffix 1) and TRIGGER 2 (suffix 2) connector.
Parameters:
<Delay> float
Range: 0 to 2^32-1
Increment: 1
*RST: 0
Default unit: sample
Example:
BB:ARB:TRIG:SOUR EXT
selects an external trigger via the TRIGGER 1 connector
BB:ARB:TRIG:DEL 200
sets a delay of 200 samples for the trigger.
[:SOURce<hw>]:BB:ARB:TRIGger[:EXTernal<1|2>]:INHibit <Inhibit>
The command specifies the number of samples by which a restart is to be inhibited fol-
lowing a trigger event. This command applies only in the case of external triggering.
The numeric suffix to EXTernal distinguishes between the external trigger via the TRIG-
GER 1 (suffix 1) and TRIGGER 2 (suffix 2) connector.
Parameters:
<Inhibit> float
Range: 0 to 67108863
*RST: 0
Default unit: sample
Example:
BB:ARB:TRIG:SOUR EXT
selects an external trigger via the TRIGGER 1 connector
BB:ARB:TRIG:INH 200
sets a restart inhibit for 200 samples following a trigger event.
[:SOURce<hw>]:BB:ARB[:TRIGger]:SEQuence <Sequence>
The command selects the trigger mode.
SOURce Subsystem