Remote Control Commands
R&S
®
SMBV100A
513Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:BB:ARB:TRIGger:SMODe <SMode>
The command selects the extended trigger mode for multi segment waveforms.
Parameters:
<SMode> SAME | NEXT | SEQuencer | NSEam
SAME
The currently selected segment is output repeatedly.
NEXT
The current segment ceases to be output as soon as a new seg-
ment is entered with command :BB:ARB:WSEG:NEXT and the
new segment starts to be output after a system-imposed signal
gap.
NSEam
The segment selected with command :BB:ARB:WSEG:NEXT is
not output until the whole of the current segment has been output
(wrap around). In this case the signal transition is seamless.
SEQuencer
The waveform files are processed according to the order and rep-
etition cycles defined in the special sequencing list file (*.wvs)
assigned to the multi segment waveform file.
This “play list” is selected with the command
BB:ARB:WSEG:SEQ:SEL.
*RST:
NEXT
Example:
SOUR2:BB:ARB:SEQ AUTO
selects trigger mode AUTO.
SOUR2:BB:ARB:TRIG:SMOD SAME
the same segment of the waveform is output repeatedly.
[:SOURce<hw>]:BB:ARB:TRIGger:SOURce <Source>
The command selects the trigger source.
Parameters:
<Source> INTernal | EXTernal
INTernal
Triggering is executed by means of the Trigger command in the
case of remote control, and by means of "Execute Trigger" in the
case of manual operation.
EXTernal
Triggering is executed by means of the signal on the TRIGGER 1
connector.
*RST: INTernal
Example:
BB:ARB:TRIG:SOUR INT
sets internal triggering.