Remote Control Commands
R&S
®
SMBV100A
528Operating Manual 1407.6062.32 ─ 08
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/user/waveform.
BB:ARB:MCAR:OFIL 'mcar1_2'
defines the file name mcar1_2.wv for the multi carrier waveform.
BB:ARB:MCAR:CLO
creates multi carrier waveform mcar1_2.wv.
The new multi carrier waveform is loaded and digital standard
"ARB" is activated.
Usage: Event
[:
SOURce<hw>]:BB:ARB:MCARrier:CLOCk?
The command queries the resulting sample rate at which the multi carrier waveform is
output by the arbitrary waveform generator. The output clock rate depends on the number
of carriers, carrier spacing and input sample rate of the leftmost or rightmost carriers.
Return values:
<Clock> float
Range: 400 to Max
Increment: 1E-3
Example:
BB:ARB:MCAR:CLOC?
queries the ARB multi carrier output clock rate.
Usage: Query only
[:SOURce<hw>]:BB:ARB:MCARrier:CREate
This command creates a multi carrier waveform using the current settings of the carrier
table. The multi carrier waveform is saved into the file defined with command
SOUR:BB:ARB:MCAR:OFIL. The file extension is *.wv.
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/user/waveform.
BB:ARB:MCAR:OFIL 'multi_wv1'
defines the file name multi_wv1.wv for the multi carrier wave-
form.
BB:ARB:MCAR:CRE
creates multi carrier waveform multi_wv1.wv.
Usage: Event
[:SOURce<hw>]:BB:ARB:MCARrier:EDIT:CARRier:DELay:STEP <Step>
The command sets the step width by which the start delays of the carriers in the defined
carrier range will be incremented.