Example:
BB:DM:TRIG:SOUR INT
sets internal triggering.
BB:DM:TRIG:SEQ ARET
sets Armed_Retrigger mode, i.e. every trigger event causes signal
generation to restart.
BB:DM:TRIG:EXEC
executes a trigger, signal generation is started.
BB:DM:TRIG:ARM:EXEC
signal generation is stopped.
BB:DM:TRIG:EXEC
executes a trigger, signal generation is started again.
Usage: Event
[:SOURce<hw>]:BB:DM:TRIGger:EXECute
The command executes a trigger. The internal trigger source must be selected using the
command:BB:DM:TRIG:SOUR INT and a trigger mode other than AUTO must be
selected using the command :BB:DM:TRIG:SEQ.
Example:
BB:DM:TRIG:SOUR INT
sets internal triggering.
BB:DM:TRIG:SEQ RETR
sets Retrigger mode, i.e. every trigger event causes signal gen-
eration to restart.
BB:DM:TRIG:EXEC
executes a trigger.
Usage: Event
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut <Output>
(enabled for "Trigger Source" External)
Enables/disables output of the signal synchronous to the external trigger event.
For or two or more R&S SMBVs configured to work in a master-slave mode for synchro-
nous signal generation:
disable this parameter in the slave instruments, in case the master instrument pro-
vides the slaves with its internal trigger signal and
use the default enabled state, if a common external trigger event is provided for the
master and the slave instruments.