Loading...
service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-89
Nur für den internen Gebrauch Service
Guided Maintenance
1014 X File open
error
Logical TFTP
error; HiPath
3000/5000 dis-
plays a mes-
sage indicating
that frame page
cannot be
opened
Wait 5 minutes then
repeat action.
adm HiPath
AllServ
e
1015 X Error
while set-
sockopt.
Server problem:
IP socket could
not be initialized
Save event
file for er-
ror analy-
sis
Shut down and re-
start server.
If error is still
present, restart the
PC.
adm HiPath
AllServ
e
1016 X Error
while
recvfrom.
HiPath 3000/
5000 no longer
replies when
files are re-
ceived
Save event
file for er-
ror analy-
sis
Connection error,
HiPath 3000/5000
HIP problems.
Check if ping is
working:
If ping is working:
wait 5 mins and re-
start server.
If ping is not work-
ing properly, check
if the “Ping unsuc-
cessful” error mes-
sage appears in the
Event Viewer.
adm HiPath
AllServ
e
1017 X Error
while
sending
to <IP-
Adr>
Logical error
when sending
data to HiPath
3000/5000
Save event
file for er-
ror analy-
sis
Unrecoverable er-
ror.
Restart server and
report error to ap-
propriate service
support.
adm HiPath
AllServ
e
1018 X Transfer
timed out
No acknowl-
edgement re-
ceived/sent
Save event
file for er-
ror analy-
sis
Possible connec-
tion interruption or
HiPath 3000/5000
HIP problems.
adm HiPath
AllServ
e
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
Event De-
fault
trap
Error
text
Meaning User reaction Cate-
gory
Source

Table of Contents