Expanding and Upgrading HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
9-34 HiPath 3000/5000 V9, Service documentation
exup.fm
Upgrading HiPath 3000
9.2.2.5 Upgrading a HiPath 3000 System Networked with HiPath 4000
Procedure
1. Upgrade the HiPath 3000 system:
a) Upgrade all HG 1500 boards to V9.
b) Convert the customer database (CDB) and reload it together with the V9 system soft-
ware.
2. Gateway Call Flag “Always use DSP” for the HiPath 4000 route
(HiPath 3000 Manager E: Settings – Lines/networking ... – Special):
Set the flag if the H.323 protocol is used for networking
(old versions of HiPath 4000).
Note: As HiPath 4000 is not EFC-enabled, activating this flag sets up gateway connec-
tions to the HiPath 4000 system.
Deactivate the flag if the SIP-Q protocol is used for networking
(new versions of HiPath 4000).
The upgrade is complete.