start_h5.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
6-17
Nur für den internen Gebrauch Startup and Administration HiPath 5000
Starting HiPath 5000
6.6.2 Integrating the HiPath 5000 Server in the Customer LAN
The settings are made under Control Panel - Network - Protocols.
Modify the IP address
Adapt the subnet mask, gateway.
Adapt the DNS entries, WINS entries.
Once the data has been customized, a reboot is required.
Test the LAN connection with a “ping” to another computer
Integrate the HiPath 5000 in the Windows domain under Control Panel - Network - Identi-
fication (a domain administrator account is required here!)
>
Network analysis must be performed before the relevant systems and applications
are installed to guarantee smooth operation in the IP customer network. Network
analysis determines the conditions under which the IP customer’s network is suit-
able for a HiPath 3000/5000 network.
The data necessary for integrating the HiPath 5000 server, for example, IP address-
es, is defined as part of network analysis and in consultation with the customer (re-
quirements specifications).