An MIB browser (available with Hewlett-Packard’s “Network Node Managers”) is required for
using SNMP functionality.
SNMP traps
The following HG 1500-specific trap classes are available:
General traps
Reboot traps
Threshold/statistic, resource/diagnostic traps,
Security traps
License traps
Traps for internal errors
The following tables list the individual traps for each of these classes. A distinction is made un-
der “Type” between hardware traps (HW) and software traps (SW).
Table 13-6 Generic SNMP Traps (MIB-2)
Trap
COLD START
WARM START
INTERFACE UP
INTERFACE DOWN
AUTHENTICATION ERROR (incorrect SNMP community name)
Table 13-7 General Traps (HG 1500-Specific)
Type
(SW/HW)
Trap Message Description
SW MSG_GW_SUCCESSFULLY_STARTE
D
Gateway successfully started
Table 13-8 Reboot Traps (HG 1500-Specific)
Type
(SW/HW)
Trap Message Description
SW MSG_CAT_H323_REBOOT Reboot with H.323
SW MSG_CAT_HSA_REBOOT Reboot with HSA