2.5.2.2 Planning Load for HiPath Systems
This section describes a dimensioning method for the various systems. In order to provide for
sufficient reserves to handle load fluctuations during operations, a so-called planning load is
defined the systems. This planning load consists of 70 % of the capacity available for call pro-
cessing (switching) transactions (see Figure below).
Figure 2-7 Planning Load for HiPath 3000/5000 Systems
The planning load values described here are taken into account in the following table as the
“maximum permissible points”.
Basic load
(e.g., polling)
Reserve for load fluctua-
tions
Planning load for call
processing
Absolute shares
70 (1-basic load)%
70 %
HiPath 3000
100 %
Relative shares
(w/o basic load)