EasyManua.ls Logo

Siemens HiPath 3000 Series - LIMLIMS Board for LAN Connection

Siemens HiPath 3000 Series
1302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
h3h5_in_the_lan.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
13-7
Nur für den internen Gebrauch HiPath 3000/5000 in the LAN Network
LIM/LIMS board for LAN connection
13.5 LIM/LIMS board for LAN connection
The boards LIM and LIMS allow the cost-effective connection of HiPath 3000 in TCP/IP-based
LANs for the central system administration, APS transfer, TeleData Office or HiPath Fault Man-
agement.
The LAN Interface Module LIM is an optional plug-in card for all central control boards of HiPath
3000 with the exception of the CBSAP (HiPath 3800), the CBCC (HiPath 3550, HiPath 3350)
from S30810-Q2935-A401 or later, and the CBRC (HiPath 3500, HiPath 3300) from S30810-
Q2935-Z401 or later. The board provides an Ethernet (10BaseT/10 megabit) LAN connector
via an 8-pin RJ45 jack.
The LAN Interface Module for SAPP LIMS is an optional plug-in card for the CBSAP central
control board in HiPath 3800. The board provides two Ethernet (10BaseT) LAN connectors via
two 8-pin RJ45 jacks:
Up to 6 TAPI 120 V2.0 can be operated via the LIM module on HiPath 3000 V4.0 SMR6 or later.
However, a maximum traffic value of 400 BHCA is permitted.
Power dialers are not released for use.

Table of Contents