h3h5_in_the_lan.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
13-69
Nur für den internen Gebrauch HiPath 3000/5000 in the LAN Network
Administration & Fault Management
SW MSG_ADMIN_REBOOT Reboot with WBM/CLI-Admin,
software upgrade or data restore
SW MSG_SYSTEM_REBOOT Automatic reboot, for example with Gar-
bage Collection
SW MSG_EXCEPTION_REBOOT Reboot with SW exception
SW ASSERTION_FAILED_EVENT Reboot following declared exception
SW EXIT_REBOOT_EVENT Reboot following exception on termina-
tion
HW MSG_DSP_REBOOT Reboot following DSP error
HW MSG_DELIC_ERROR Reboot following DELIC error
Table 13-9 Threshold/Statistic, Resource/Diagnostic Traps (HG 1500-Specific)
Type
(SW/HW)
Trap Message Description
HW MSG_IP_LINK_FAILURE IP-Link 1 up/down
HW MSG_IP_LINK2_FAILURE IP Link 2 up/down
HW MSG_OAM_HIGH_TEMPERATURE_EXCEPTION Temperature limit reached
(too hot)
SW MSG_GW_OBJ_MEMORY_EXHAUSTED Out of memory
SW MSG_GW_OBJ_ALLOC_FAILED Out of memory (signaled by
external source)
SW MSG_GW_OBJ_MEMORY_INCONSISTENT Memory inconsistency
SW MSG_TLS_POOL_SIZE_EXCEEDED No more internal pools
SW MSG_OAM_RAM_THRESHOLD_REACHED RAM limit reached
SW MSG_OAM_DMA_RAM_THRESHOLD_REACHED DRAM limit reached
SW MSG_OAM_THRESHOLD_REACHED Limit reached, for example,
for flash memory or IP pools
SW MSG_DVMGR_LAYER2_SERVICE_TRAP B channel up/down
Table 13-8 Reboot Traps (HG 1500-Specific)
Type
(SW/HW)
Trap Message Description

Table of Contents

Related product manuals