EasyManua.ls Logo

Siemens HiPath 3000 Series - Page 1248

Siemens HiPath 3000 Series
1302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Specific Attributes
HiPath HG 1500 V7
Issue: 18
th
April 2007 Page - 14 -
Siemens Enterprise Communications GmbH & Co KG
Application Function Type A-Prot.
M-
Prot.
T-
Prot.
D-
Ports
A-
Ports
Remarks
.
SNMP (SET/GET)
(Phones) SNMP
SET/GET-Functionality
server SNMP --- UDP 161 Def: SNMP (Set/Get)
.
SNMP Trap (oP410)
SNMP Trap function
client SNMP --- UDP
161
162
Def: SNMP Trap (oP410)
QoS Data Collection Unit (QCU) phones Send QoS reports,
.
QCU client 12010
Client application
which sends QDC data
to the QCU
client SNMP --- UDP 12010
0 -
65535
Def: QCU receiving Port
User Applications (oP410 HFA) bundle of user functions of HFA phone oP410
.
CTI Service (TCP) CTI
Service in oP410
client Cornet TS --- TCP 5105 Def: CTI Service oP410
.
JAVA (optiPoints)
JAVA applications in
phones
client HTTP --- TCP 9200
0 -
65535
Def: Java default port in optiPoint phones
.
LDAP Access
(optiPoint phones)
Directory access via
LDAP
client LDAP --- TCP 389
0 -
65535
Def: LDAP
.
WAP client (TCP) for
WAP access to WAP
services (server)
client WAP --- TCP 9200
0 -
65535
Def: WAP connectionless session service
(IANA)

Table of Contents