Boards for HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-18 HiPath 3000/5000 V9, Service documentation
boards.fm
Central Board
Subboards
The following subboards can be used depending on the application:
● Clock module CMA or CMS (optional)
● MMC multimedia card
● IMODN integrated modem card new (optional)
● Music on hold (optional):
– MPPI (Product of BEYERTONE GmbH)
– MUSIC (Product of Sound Player GmbH)
– EXM
● Entry Voice Mail EVM (optional): Pluggable up to HiPath 3000/5000 V7, securely soldered
as of HiPath 3000/5000 V8.
● LAN Interface Module LIM (optional, for CBCC S30810-Q2935-A301 only)
Outputs, interfaces
● Ethernet (10 BaseT)/10 MBit) LAN interface, only in CBCC S30810-Q2935-A401
The interface can, for example, be used for the following applications:
– For administration using HiPath 3000 Manager E
– For the TAPI 120/170 connection via the CSTA interface. Bear in mind, however, that
the number of BHCAs (Busy Hour Call Attempts = number of connection attempts dur-
ing busy traffic hours) is restricted to 400 at a maximum of six CSTA links for the TAPI
120/170 connection. The use of “power dialers” is not approved.
– For the output of call data
The ETHERNET-LAN interface is deactivated by the system software deactivated as soon
as an HG 1500 board is inserted.
● Eight digital U
P0/E
subscriber lines
For example, U
P0/E
workpoint clients or BS3/1 base stations for HiPath Cordless Office can
be connected here.
● Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
CBCC S30810-Q2935-A401: The interfaces supply a ring voltage of approx. 65 V
eff
.
CBCC S30810-Q2935-A301: The T/R interfaces supply a ring voltage of approx. 35 V
eff
.
Depending on the terminals connected, we cannot exclude the possibility of errors occur-