boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-129
Nur für den internen Gebrauch Boards for HiPath 3000
Peripheral boards
Technical connection conditions
● Maximum supply current: approximately 34 mA; maximum supply voltage: approximately
40 V DC
● Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maxi-
mum
● Range, see Section 2.7
● Loop current detection > 10 mA
● Ground button detection > 20 mA
● The transmission technology is set according to the specific country through the respec-
tively entered country code (for country initialization, see Chapter 5, “Starting Up HiPath
3000”).
17
red/brn 11 17a
Port 17
99a
not
used
in
SLA16N
brn/red 31 17b 34 9b
18
red/gry 02 18a
Port 18
10 10a
gry/red 22 18b 35 10b
19
blk/blu 13 19a
Port 19
11 11a
blu/blk 33 19b 36 11b
20
blk/ora 04 20a
Port 20
12 12a
ora/blk 24 20b 37 12b
21
blk/grn 15 21a
Port 21
13 13a
grn/blk 35 21b 38 13b
22
blk/brn 06 22a
Port 22
14 14a
brn/blk 26 22b 39 14b
23
blk/gry 17 23a
Port 23
15 15a
gry/blk 37 23b 40 15b
24
yel/blu 08 24a
Port 24
16 16a
blu/yel 28 24b 41 16b
1 see “Abbreviations for colors“ at the start of Section 3.3.
Table 3-55 SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (for U.S. only)
#
a-wire
(tip)
1
b-wire
(ring)1
SU connector
SLA16N, SLA24N CHAMP jack, MDF Notes
BP: Xx8 BP: Xx9