Boards for HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-282 HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Jumper for setting the procedure for analog trunk interfaces
The procedure for the analog trunk interfaces is set via jumper X100 and X101.
Loop start setting = pins 1–2 closed (default)
Ground start setting = Pins 2 – 3 closed [not with IM and BRA]
LED statuses and their meanings
Cable and connector assignment
For connecting to the SIVAPAC connector on the backplane: Table 3-135
For connecting to the connector panels using RJ45 jacks: Table 3-136
For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-137
For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-138
Table 3-134 TMANI8 - LED States
Red LED Green
LED
Status Action
Off Off Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On Off Board is receiving power and board test is in
progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Replace board.
Loadware loading not successfully complet-
ed. Board is faulty.
Replace board.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was de-
activated using HiPath 3000/5000 Manager
E.
Check whether the board
was deactivated using Hi-
Path 3000/5000 Manager
E. If not, replace board.
Flashing Off Loadware is being loaded.
Off On Board test completed successfully. Board is
OK (idle state).
Off Flashing At least one subscriber line circuit is activat-
ed.