EasyManua.ls Logo

Siemens HiPath 3000 Series - Page 494

Siemens HiPath 3000 Series
1302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Boards for HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-362 HiPath 3000/5000 V9, Service documentation
boards.fm
Options
ANI4 module contact assignments
Red LED - Checksum Status
On The received caller ID signal has a checksum error.
The LED is reset after the next correct caller ID mes-
sage is received.
If the red LED is on after ev-
ery call: the FSK signal is
provided, but is not Bellcore-
compliant on the customer
side. This must be corrected
by the service provider.
Off Checksum is OK.
Table 3-177 ANI4 (for selected countries only) - Contact Assignments
Contact Connector X3
Component Side
Connector X3
Solder Side
Connector X4
1 -- Not assigned a-wire (tip), trunk 1
2 b-wire (ring), trunk 1 -- b-wire (ring), trunk 1
3 -- a-wire (tip), trunk 1 a-wire (tip), trunk 2
4 b-wire (ring), trunk 2 -- b-wire (ring), trunk 2
5 -- a-wire (tip), trunk 2 a-wire (tip), trunk 3
6 b-wire (ring), trunk 3 -- b-wire (ring), trunk 3
7 -- a-wire (tip), trunk 3 a-wire (tip), trunk 4
8 b-wire (ring), trunk 4 -- b-wire (ring), trunk 4
9 -- a-wire (tip), trunk 4
10 GMZ --
GMZ= Call charging module assignment
Table 3-176 ANI4 (for selected countries only) - LED Statuses for Trunk 1
LED Meaning Action

Table of Contents

Related product manuals